Combustible Gas Leak Detector Methane Gas Leakage Detection Sound Light Alarm Tester, 0~10000ppm 0~20%LEL
Combustible Gas Leak Detector Methane Gas Leakage Detection Sound Light Alarm Tester, 0~10000ppm 0~20%LEL
30 Days Lowest Price Guarantee

Combustible Gas Leak Detector Methane Gas Leakage Detection Sound Light Alarm Tester, 0~10000ppm 0~20%LEL

$ 329.29

DESCRIPTION

Technical indexes:
1)Principle for sensor measurement: semi-conductive method
2)Detectable gas: methane gas
3)Measurement range: 0~10000ppm 0~20%LEL (LEL: Lower explosive limit)
4)Resolution: 1ppm 0.1%LEL
5)Error: ±2%
6)Response time: 7)Measurement temperature range: -5℃~50℃
Measurement humidity range: 25%~90%RH
8)Operation environment temperature: -5℃~50℃
Operation environment humidity: 9)Display: large screen digital LCD
10)Alarming: acousto-optic alarming
11)Electric current: Cautions
1. To ensure accurate measuring, regularly zero calibration is needed. The operations are carried out by professionals. The specified air chamber and verified standard gas should be used in calibration with the regular flow rate.
2. This meter is mainly used for measuring the low level of methane gas (absolute concentration below 20%LEL). The contact with methane gas of concentration above 20% should be avoided. When incidental contact is made with high concentration methane gas, it will affect the normal working on sensor. Leaving the meter in clean air not less than 2 hours and go ahead the next measurement.
3. This instrument, especially the probe, should avoid falling down, moisture, and keep clean. Do not touch other toxic gas. Otherwise it will cause irreparable damage.
4. This instrument should be handled gently. Avoid contact with water or other fluid, and keep it clean.
5. The batteries should be taken out and stored in the dry and clean gas environment for storage.
6. Requiring Warn-up not less than 30 minutes after using the meter again if long time not used.
  • The gas leak detector can be used in the natural gas is leaked indoors and outdoors, where the gas is produced, stored, used, etc., such as chemical, petroleum, metallurgy, oil depot, LPG (Liquefied Petroleum Gas) station, gas transmission and distribution, etc. to detect the leakage and show the leaking concentration or explosion percentage with a digital display.
  • This device can set two-level alarming value. The detector can rise the acousto-optic alarming when the detected concentration reaches the preset value.
  • It also can synchronously measure that time's temperature and humidity when measuring methane gas.
  • Long gooseneck sensor for easy access into hard to reach locations. Easy to use
  • Principle for sensor measurement: semi-conductive method;Electric current:
The gas leak detector can be used in the natural gas is leaked indoors and outdoors, where the gas is produced, stored, used, etc., such as chemical, petroleum, metallurgy, oil depot, LPG (Liquefied Petroleum Gas) station, gas transmission and distribution, etc. to detect the leakage and show the leaking concentration or explosion percentage with a digital display.Malxs