DESCRIPTION

Monitor up to 24 single phase circuit loads or 8 separate 3-phase circuit loads simultaneously when 24 CTs are installed. . Modbus/RTU over RS485 communication, Max Voltage : 80~350 VAC (L-N), 600 VAC (L-L), Frequency : 50 or 60 Hz. Display cumulative kWh, real time kW load, volts per phase, amps per phase, power factor per phase, apparent power (kVA), reactive power (kVAr), reactive energy (KVArh), and frequency.Auxiliary Power: AC 120 or 240V, ±10% 2 lines, 16 characters LCD display for easy set-up and programing. Can be used in the following configurations: 3 Phase 4 Wire; 3 Phase 3 Wire, 2 Phase 3 Wire, 1 Phase 3 Wire, 1 Phase 2 Wire Non-volatile Memory, the stored data is maintained through power outages. No conversion factor or multiplier required Optional split core CT (DAE CT-100S, CT-200S, CT-400S, CT-600S). Compatible with Touch Panel (like DAE ACS35, see DAE website for details) for remote display. Current Transformers (CTs) are not direction sensitive. It does not matter if the contractors install the CTs with wrong direction of current. DAE meters can detect it and compensate it. DAE's CTs are exactly the same and exchangeable among all the meters including Polaris 1000, 1500, 2000, 2500, 3000 and SMB 350 multi-circuit, multi-function meters. Current sensors (CTs) accuracy will not be affected when the CTs are mounted up to 2000 feet away from the meter. Applications: Branch circuit monitoring, Load surveying, Load monitoring from a host PC using remote communication, Building automation monitoring system, Lighting failure monitoring Five year warranty from the Seller  See DAE Controls website for more information
  • UL/CUL Listed, CE and FCC approved
  • Ready to interface with DAE software EnergyLink400 for remote reading and billing.
  • Wireless remote reading available with DAE RF converters.
  • Cloud System available with DAE gateway
  • Monitor up to 24 single phase circuit loads or 8 separate 3-phase circuit loads simultaneously when 24 CTs are installed.. Modbus/RTU over RS485 communication, Max Voltage : 80~350 VAC (L-N), 600 VAC (L-L), Frequency : 50 or 60 Hz. Display cumulative kWh, real time kW load, volts per phase, amps per phase, power factor per phase, apparent power (kVA), reactive power (kVAr), reactive energy (KVArh), and frequency.